Introduction:
The LAB
Advanced Radar Training System offers Model ARTS realistic
classroom training, in radar techniques, enabling instructors
and students to study the principles involved in pulse radar
systems. The system is designed with low power for safe
operation.
The system
is provided with three targets, which are simultaneously tracked
to an operating range of 2 to 10mtrs (approx.). The radar
training system detects the targets when they approach or leave
the scanned area at different speeds, from selected ranges (cms
to kms), and at different azimuth settings (0° -360° ).
This
Advanced Radar Training system (ARTS) operates over a short
range of 2-10 mtrs (approx.), providing instruction and
observation of all phases of the radar system operation. This
trainer is unlike commercial or military radar systems which do
not make effective basic trainers, since they use higher
radiated power AC voltages (which are dangerous) and targets
that are not within visual range. The Trainer operates on
10.5GHz and uses a Horn antenna system. It consists of a
microwave transceiver and a stepper motor. A slow-scan antenna
scans the laboratory for targets, which move electronically at
different speeds with the help of Stepper motor. The PC software
controls the antenna rotation speed.
The
targets are individually identified on the Plan Position
Indicator using LAB-Radar 3.0 Software in PC, with quadrant arcs
and range markers in meters or kilometers. The range display is
switch-selectable for far-out or close-in viewing.
The
comprehensive laboratory manual includes the study of radar-type
electronic circuits.
ARTS consists
of:
Radar
signal processing unit – 1 no.
Stepper
motor unit – 1no.
RF
Transceiver – 1no.
Function
Generator – 1no.
LAB-Radar
1.0 Software CD – 1no.
Shielded
Cables – 1 set.
Instruction manual – 1set.
Artificial Targets – 1 set.
Features:
-
Incorporates
Technologically Advanced Integrated Transmitter and
eiver
-
Scans, Calculates, and Displays
Range and Azimuth Measurements.
-
Horn Antenna with rotating base. (Stepper motor)
-
Demonstrates and Teaches Moving Target Concepts.
-
LAB-Radar 3.0 Software is provided with the trainer
for real time
-
measurement in the PC.
-
High speed Data Acquisition card is provided with the
trainer (in-built).
-
Hand Gloves and Shielded cables are provided to avoid
ESD.
LIST OF
EXPERIMENTS THAT CAN BE CONDUCTED ON THE TRAINER:
-
Introduction to the Experimental Radar System.
-
Study of
FM Doppler radar System, outputs can be observed in the CRO.
-
Study of
Radar Display Methods on computer (PPI Method).
-
Study of
Transmitter and Receiver.
-
Study of
reflections from artificial targets, outputs can be observed
in the CRO.
-
Study of
measurement of distance of a stationary target, outputs can
be observed in the CRO.
-
Study of
measurement of Azimuth angle, velocity of a moving target,
outputs can be observed in the CRO.
SPECIFICATIONS OF ADVANCED RADAR TRAINING SYSYTEMS
EQUIPMENT
INCLUDED:
-
RF Source : 10.5GHz.
-
Type : Integrated Transmitter/ Receiver.
-
Band : X – Band.
-
Output Power : 10 milli watts.
-
Tuning : Electronic Tuning 40MHz.
-
Operating Voltage : +8 to +10VDC.
-
Operating Current : 200mA.
-
Normal Sensitivity : -110dBc.
HORN ANTENNA:
Type : Horn
Antenna.
Band :
X-Band.
Bandwidth :
10.5GHz.
E-Plane : 70°
.
H-Plane : 30°
.
ARTIFICIAL TARGETS:
3 Targets;
-
Aluminium.
-
Wooden.
-
Plastic.
Tripod Stand
: 1No.
Range :
2meters to 10meters.
Function Generator (Included)
High quality
Function generator with digital read out is provided along with
the ARTS.
LAB-RADAR 3.0 SOFTWARE:
Lab-Radar 3.0
is a software application developed for Educational purpose to
help the Students to learn about RADAR PROCESSING SYSTEM.
Observing radar results in Oscilloscope (CRO) may not give you
the results in realistic manner. But the PPI (LAB-Radar 3.0)
gives you the radar results more realistically and in graphical
manner. Our Lab-Radar 3.0 software provides you a real time
output of Radars using High speed Data Acquisition.
SPECIAL FEATURES:
LAB-Radar 3.0
gives you,
-
Target
Indication with multicolor effect
-
Realistic scanner with Rings, Grids.
-
PPI,A-Scope
-
Outputs
in print-ready format.
-
Interfacing with Radar unit.
-
Self
test, Help, Video demos
-
User
administration
-
Radar
Rotation speed controller
-
Observation saving facility.
-
Guided
tour.
SYSTEM REQUIREMENTS:
-
Intel
pentium III 1.8 GHz or higher
-
15"
color monitor (1028x764 pixels)
-
2 GB
Hard disk or higher
-
128 MB
RAM or higher
-
Scroll
PS/2 mouse
-
104
Keys Keyboard
-
CD-ROM
Drive
-
9-pin
COM port
-
Printer
(optional)
-
Speaker
(optional)
INSTRUCTION MANUAL:
Detailed Step
– By – Step instruction manual will be supplied.
EQUIPMENT REQUIRED (INCLUDE):
-
Radar
processing unit
-
Stepper
motor unit
-
RF
Transceiver
-
Function
Generator
-
LAB-Radar
3.0 software
-
Hand
gloves & Shielded Cables
-
Artificial Targets
Equipment Required (Not Included)
-
Computer.
-
Oscilloscope of 100MHz or Spectrum Analyzer.
-
Digital
Multi meter.
OPERATING VOLTAGE:
Power:
230V Ac mains operated.
 |